Trulite Glass & Aluminum Solution’s 3100 Resistor Hurricane Impact Storefront is engineered, designed and tested in accordance with the demanding Standards of Miami-Dade County (NOA) and the Florida Building Code (FBC). The 1-1/4″ x 4-1/2″ systems are available in shear block assembly and are ideal for single span Impact Resistant storefront applications. The 3100 series is glazed with 9/16″ or 1-5/16″ insulating laminated glazing infill. The front set glazed 3100 system can use 9/16″ laminated glass as well, and are both interior glazed. Trulite’s 351 Impact Resistant entrances are easily integrated into these systems. Trulite has the unique ability to produce and furnish the complete impact resistant system and glazing, which is an added convenience for the building team. The design of these systems has become the standard for storefront systems in high velocity hurricane zones.
The Resistor Impact 3100 Series storefront system is designed for hurricane impact protection in commercial and institutional projects requiring high wind-load resistance:
Coastal and hurricane-prone retail and office buildings – Meets Miami-Dade and Florida Building Code requirements for impact resistance.
Schools, municipal, and government facilities – Protects occupants and property in critical infrastructure.
Healthcare, hospitality, and mixed-use developments – Ensures continuity and safety while maintaining modern aesthetics.
New construction and retrofits – Integrates seamlessly with Trulite entrances, curtain walls, and accessories for a complete building envelope.
1-1/4″ × 4-1/2″ Front-Set Storefront Framing – Designed for impact resistance with shear block assembly.
Glazing Options – Accommodates 9/16″ laminated or 1-5/16″ insulating glass units with Saflex IIIG, Saflex HP, or SentryGlas interlayers.
Small- and Large-Missile Rated – Tested to Miami-Dade TAS protocols for severe weather performance.
Qualified for 100 psf Load Pressure – Supports openings up to 12′-0″ (144″) in height.
Product Approvals – Miami-Dade NOA#15-0122.02, Florida Building Product Approval #18474.1, and Texas Department of Insurance (TDI) #CWSF-43.
Direct Structural Attachment – Perimeter framing allows secure anchorage without blind seals or strap anchors.
Premium Finishes – Available in Architectural Class I/II anodized coatings or AAMA 2604/2605 high-performance organic coatings.
Air Infiltration (ASTM E283) – Does not exceed 0.06 cfm/ft² at 6.24 psf static pressure.
Water Resistance (ASTM E331 / AAMA 501) – No uncontrolled water infiltration at 15 psf.
Structural Performance (ASTM E330 / TAS 202) – Maximum allowable deflection of L/180 or 3/4″, whichever is less, at 1.5× design load without glass breakage or permanent set.
Impact Resistance (TAS 201 / TAS 203 / ASTM E1886) – Meets large- and small-missile hurricane impact standards.
Thermal Movement – Handles temperature swings without compromising seals or structural elements.
Durability & Warranty – Backed by Trulite’s two-year standard manufacturer’s warranty and limited lifetime corner warranty on hurricane impact-resistant entrance doors.